居里-韦斯定律
此条目需要扩充。 (2017年6月22日) |
居里-韦斯定律为居里定律的修正公式,用来补足该公式的不足。当一物质的温度大于居里温度()时,其磁化率与温度的关系式为:
其中:
- 是该物质的居里常数
- 是绝对温度,单位为
- 是该物质的居里温度,单位为
基本概念
一个磁性物质的磁化矢量(或称磁化强度)代表单位体积该物质的磁矩强度。而磁矩可能由原子内的电子运动或者是自旋所产生。而净磁化矢量可能由外加磁场诱导产生,甚至可能不需要施加外加磁场也能产生磁化矢量(例如足够低温状态下的铁),其中后者被称之为自发磁化。
而其他与铁拥有同样性质的物质,如镍与磁铁矿,被称之为铁磁性物质。铁磁性物质在足够低的温度下将会不须施加外部磁场也会产生磁性,而该临界温度称之为居里温度。
局限性
有许多材料的磁化特性在居里点附近显现出明显的敏感性,而由于居里-韦斯定律基于平均场近似而无法描述这种现象。
In many materials the Curie–Weiss law fails to describe the susceptibility in the immediate vicinity of the Curie point, since it is based on a mean-field approximation. Instead, there is a critical behavior of the form
with the critical exponent γ. However, at temperatures T ≫ Tc the expression of the Curie–Weiss law still holds true, but with Tc replaced by a temperature Θ that is somewhat higher than the actual Curie temperature. Some authors call Θ the Weiss constant to distinguish it from the temperature of the actual Curie point.
Classical approaches to magnetic susceptibility and Bohr–van Leeuwen theorem
According to Bohr–van Leeuwen theorem when statistical mechanics and classical mechanics are applied consistently, the thermal average of the magnetization is always zero. Magnetism cannot be explained without quantum mechanics. However we list some classical approaches to it as they are easy to understand and relate to even though they are incorrect.
The magnetic moment of a free atom is due to the orbital angular momentum and spin of its electrons and nucleus. When the atoms are such that their shells are completely filled they do not have any net magnetic dipole moment in the absence of external magnetic field. When present, such field distorts the trajectories (classical concept) of the electrons so that the applied field could be opposed as predicted by the Lenz's law. In other words the net magnetic dipole induced by the external field is in the opposite direction and such materials are repelled by it. These are called diamagnetic materials.
Sometimes an atom has a net magnetic dipole moment even in the absence of an external magnetic field. The contributions of the individual electrons and nucleus to the total angular momentum do not cancel each other. This happens when the shells of the atoms are not fully filled up (Hund's Rule). A collection of such atoms however may not have any net magnetic moment as these dipoles are not aligned. An external magnetic field may serve to align them to some extent and develop a net magnetic moment per volume. Such alignment is temperature dependent as thermal agitation acts to disorient the dipoles. Such materials are called paramagnetic.
In some materials, the atoms (with net magnetic dipole moments) can interact with each other to align themselves even in the absence of any external magnetic field when the thermal agitation is low enough. Alignment could be parallel (ferromagnetism) or anti-parallel. In case of anti-parallel, the dipole moments may or may not cancel each other (antiferromagnetism, ferrimagnetism).
Density matrix approach to magnetic susceptibility
We take a very simple situation in which each atom can be approximated as a two state system. The thermal energy is so low that the atom is in ground state. In this ground state the atom is assumed to have no net orbital angular momentum but only one unpaired electron to give it a spin of half. In the presence of an external magnetic field the ground state will split into two states having energy difference proportional to the applied field. The spin of the unpaired electron is parallel to the field in the higher energy state and anti-parallel in the lower one.
A density matrix, , is a matrix that describes a quantum system in a mixed state, a statistical ensemble of several quantum states (here several similar 2-state atoms). This should be contrasted with a single state vector that describes a quantum system in a pure state. The expectation value of a measurement, , over the ensemble is . In terms of a complete set of states, , one can write
Von Neumann’s equation tells us how the density matrix evolves with time.
In equilibrium, one has , and the allowed density matrices are . The canonical ensemble has where .
For the 2-state system, we can write . Here is the gyromagnetic ratio. Hence , and
From which
Explanation of para and diamagnetism using perturbation theory
In the presence of a uniform external magnetic field along the z-direction, the Hamiltonian of the atom changes by
where are positive real numbers which are independent of which atom we are looking at but depends on the mass and the charge of the electron. corresponds to individual electrons of the atom.
We apply second order perturbation theory to this situation. This is justified by the fact that even for highest presently attainable field strengths, the shifts in the energy level due to is quite small w.r.t. atomic excitation energies. Degeneracy of the original Hamiltonian is handled by choosing a basis which diagonalizes in the degenerate subspaces. Let be such a basis for the state of the atom (rather the electrons in the atom). Let be the change in energy in . So we get
In our case we can ignore and higher order terms. We get
In case of diamagnetic material, the first two terms are absent as they don't have any angular momentum in their ground state. In case of paramagnetic material all the three terms contribute.
Adding spin-spin interaction in the Hamiltonian: Ising model
So far we have assumed that the atoms do not interact with each other. Even though this is a reasonable assumption in case of diamagnetic and paramagnetic substances, this assumption fails in case of ferromagnetism where the spins of the atom try to align with each other to the extent permitted by the thermal agitation. In this case we have to consider the Hamiltonian of the ensemble of the atom. Such a Hamiltonian will contain all the terms described above for individual atoms and terms corresponding to the interaction among the pairs of atom. Ising model is one of the simplest approximation of such pairwise interaction.
Here the two atoms of a pair are at . Their interaction is determined by their distance vector . In order to simplify calculation it is often assumed that interaction happens between neighboring atoms only and is a constant. The effect of such interaction is often approximated as a mean field and in our case the Weiss field.
Modification of Curie Law due to Weiss field
The Curie-Weiss Law is an adapted version of Curie's Law, which for a paramagnetic material may be written in SI units as[1]
Here µ0 is the permeability of free space; M the magnetization (magnetic moment per unit volume), B=µ0H is the magnetic field, and C the material-specific Curie constant:
where kB is Boltzmann's constant, N the number of magnetic atoms (or molecules) per unit volume, g the Landé g-factor, μB the Bohr magneton, J the angular momentum quantum number.[2]
For the Curie-Weiss Law the total magnetic field is B+λM where λ is the Weiss molecular field constant and then
- →
which can be rearranged to get
which is the Curie-Weiss Law
where the Curie Temperature TC is
参见
注释
参考资料
- Kittel, Charles. Introduction to solid state physics 7th. New York [u.a.]: Wiley. 1996. ISBN 978-0471111818.
- Hall, H. E. Hook, J. R. Solid state physics 2nd. Chichester: Wiley. 1994. ISBN 0471928054.
- Levy, Robert A. Principles of Solid State Physics. Academic Press. 1968. ISBN 978-0124457508.
- Neil Ashcroft, David Mermin. Solid State Physics. 1976.
- http://theory.tifr.res.in/~sgupta/courses/qm2013/hand5.pdf (页面存档备份,存于互联网档案馆)